Back to top
TAI-901(A) Cooker Type Autoclave (Stainless Steel)
TAI-901(A) Cooker Type Autoclave (Stainless Steel)

TAI-901(A) Cooker Type Autoclave (Stainless Steel)

MOQ : 1 Unit

TAI-901(A) Cooker Type Autoclave (Stainless Steel) Specification

  • Type
  • Cooker Type Autoclave
  • Chamber Size
  • 225 275 mm
  • Chamber Thickness
  • High-Grade Stainless Steel
  • Outer Size
  • 225 275 mm
  • Door Type
  • Manual Twist Lock
  • Design Pressure
  • 1.05 kg/cm2
  • Working Pressure
  • 15 psi
  • Design Temperature
  • 126C
  • Heat Uniform
  • Moist Heat Throughout
  • Insulation
  • Double Wall (Stainless)
  • Net Weight
  • Approx 8 Kg
  • Recording Parameters
  • Pressure Gauge
  • Steam
  • Direct Steam
  • Sterilizing Temperature
  • 121C
  • Working Temperature
  • 121C
  • Sterilization Time
  • 15-30 Minutes
  • Temperature Scope
  • 110C - 126C
  • Piping System
  • Stainless Steel
  • Valves
  • Safety & Exhaust Valve
  • Power Consumption
  • Manual/No Power
  • Drain Valve
  • Present
  • Operation
  • Manual
  • Finish
  • Polished Exterior
  • Size (inches)
  • 09 11
  • Mounting
  • Tripod Stand
  • Usage
  • Laboratory Sterilization
  • Cover Lock
  • Gasketed Lid
  • Handles
  • Ergonomic Black Handles
  • Material
  • Stainless Steel
  • Gauge Type
  • Analog Pressure Gauge
  • Capacity
  • 13 Liters
 

TAI-901(A) Cooker Type Autoclave (Stainless Steel) Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 5-7 Days
 

About TAI-901(A) Cooker Type Autoclave (Stainless Steel)



Order today and experience the world-class performance of the TAI-901(A) Cooker Type Autoclave (Stainless Steel), designed for professional laboratory sterilization. With a generous 13-liter capacity, this gorgeous autoclave features a polished exterior, ergonomic black handles, and a secure gasketed lid. Its high-grade stainless steel construction and double-wall insulation ensure incomparable heat retention and moisture uniformity. The analog pressure gauge and robust safety features provide peace of mind during manual operation. Last chance to order this exceptional autoclave-combine reliability, efficiency, and durability in your workspace.

Versatile Application Areas for Sterilization

The TAI-901(A) Cooker Type Autoclave is not limited to laboratory glassware sterilization. With its durable stainless steel surface and polished finish, it is perfect for sterilizing instruments in hospitals, dental clinics, pharmaceutical facilities, and research laboratories. Its ergonomic design and tripod stand facilitate placement on various surfaces at laboratory sites, providing effective sterilization wherever precision and reliability are required.


Efficient Supply and Flexible Payment Options

Take advantage of our sale price and quick dispatch for the TAI-901(A) Cooker Type Autoclave. We support seamless packing & dispatch operations, ensuring fast delivery to national and international destinations. With supply ability tailored to bulk and individual orders, flexible payment terms, and a strong presence as distributor, exporter, importer, manufacturer, and supplier, we primarily export to markets worldwide, including India. Secure your order and benefit from unmatched supply reliability.


FAQ's of TAI-901(A) Cooker Type Autoclave (Stainless Steel):


Q: How does the TAI-901(A) Autoclave achieve effective sterilization in the laboratory?

A: The TAI-901(A) uses moist heat at a working temperature of 121C and pressure of 15 psi. Its direct steam system and double-wall stainless steel insulation ensure heat uniformity, providing thorough sterilization for laboratory glassware and instruments.

Q: What are the main benefits of the polished stainless steel construction?

A: The polished stainless steel not only provides a gorgeous and professional look but also maximizes durability, resists corrosion, and simplifies cleaning after use, ensuring longevity and hygiene during every sterilization process.

Q: Where can the TAI-901(A) Autoclave be applied aside from laboratories?

A: Beyond laboratories, this autoclave is suitable for sterilization tasks in hospitals, dental clinics, and pharmaceutical units, as well as research institutes that require reliable, high-capacity sterilization.

Q: What is the recommended sterilization time and temperature range for usage?

A: For optimal sterilization, a temperature of 121C and a time range of 15-30 minutes are recommended, with the temperature scope adjustable between 110C and 126C depending on load and requirements.

Q: How is safety ensured during the operation of the autoclave?

A: Safety is maintained via robust features such as a gasketed lid, manual twist lock, analog pressure gauge, and integrated safety and exhaust valves, all designed to prevent overpressure and ensure operator safety throughout the sterilization process.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Cooker Type Autoclave Category

TAI-901(A) Cooker Type Autoclave (Powder Coated)

TAI-901(A) Cooker Type Autoclave (Powder Coated)

Minimum Order Quantity : 1 Unit

Outer Size : 300 300 mm (12 12 inches)

Chamber Size : 300 300 mm (12 12 inches)

Type : Other, Cooker Type Autoclave

Steam : Yes

TAI-901(A) Cooker Type Autoclave (Aluminium)

TAI-901(A) Cooker Type Autoclave (Aluminium)

Minimum Order Quantity : 1 Unit

Outer Size : 300 500 mm

Chamber Size : 12 20 inches

Type : Other, Cooker Type

Net Weight : 40 Liters